Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Open Forum Infect Dis ; 10(1): ofac701, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2222684

ABSTRACT

During a household-transmission field study using COVID-19 antigen rapid diagnostic tests (Ag-RDT), a common test strip lot was identified among 3 participants with false-positive results. In blinded laboratory evaluation, this lot exhibited a significantly higher false-positive rate than other lots. Because a positive Ag-RDT result often prompts action, reducing lot-specific false positives can maintain confidence and actionability of true-positive Ag-RDT results.

2.
Virol J ; 19(1): 202, 2022 Dec 01.
Article in English | MEDLINE | ID: covidwho-2153609

ABSTRACT

BACKGROUND: The objective of our investigation was to better understand barriers to implementation of self-administered antigen screening testing for SARS-CoV-2 at institutions of higher education (IHE). METHODS: Using the Quidel QuickVue At-Home COVID-19 Test, 1347 IHE students and staff were asked to test twice weekly for seven weeks. We assessed seroconversion using baseline and endline serum specimens. Online surveys assessed acceptability. RESULTS: Participants reported 9971 self-administered antigen test results. Among participants who were not antibody positive at baseline, the median number of tests reported was eight. Among 324 participants seronegative at baseline, with endline antibody results and ≥ 1 self-administered antigen test results, there were five COVID-19 infections; only one was detected by self-administered antigen test (sensitivity = 20%). Acceptability of self-administered antigen tests was high. CONCLUSIONS: Twice-weekly serial self-administered antigen testing in a low prevalence period had low utility in this investigation. Issues of testing fatigue will be important to address in future testing strategies.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Students , Immunologic Tests , Seroconversion
3.
Am J Clin Pathol ; 156(3): 370-380, 2021 08 04.
Article in English | MEDLINE | ID: covidwho-1322609

ABSTRACT

OBJECTIVES: The Abbot ID NOW COVID-19 assay and Quidel Sofia 2 SARS Antigen FIA are point-of-care assays that offer rapid testing for severe acute respiratory syndrome coronavirus 2 viral RNA and nucleocapsid protein, respectively. Given the utility of these devices in the field, we investigated the feasibility and safety of using the ID NOW and Sofia assays in the public health response to the coronavirus disease 2019 pandemic and in future public health emergencies. METHODS: A combination of utilization and contamination testing in addition to a review of instrument workflows was conducted. RESULTS: Utilization testing demonstrated that both tests are intuitive, associated with high user test success (85%) in our study, and could be implemented by staff after minimal training. Contamination tests revealed potential biosafety concerns due to the open design of the ID NOW instrument and the transfer mechanisms with the Sofia. When comparing the workflow of the ID NOW and the Sofia, we found that the ID NOW was more user-friendly and that the transfer technology reduces the chance of contamination. CONCLUSIONS: The ID NOW, Sofia, and other emerging point-of-care tests should be used only after careful consideration of testing workflow, biosafety risk mitigations, and appropriate staff training.


Subject(s)
Antigens, Viral/analysis , COVID-19 Testing , COVID-19/diagnosis , Pandemics , Point-of-Care Testing , SARS-CoV-2/immunology , COVID-19/epidemiology , COVID-19/virology , Containment of Biohazards , Equipment Safety , Feasibility Studies , Humans , Risk Assessment , SARS-CoV-2/isolation & purification
4.
J Clin Virol ; 141: 104900, 2021 08.
Article in English | MEDLINE | ID: covidwho-1272521

ABSTRACT

More than one year into a global pandemic, SARS-CoV-2 is now defined by a variety of rapidly evolving variant lineages. Several FDA authorized molecular diagnostic tests have been impacted by viral variation, while no reports of viral variation affecting antigen test performance have occurred to date. While determining the analytical sensitivity of the Quidel Sofia SARS Antigen FIA test (Sofia 2), we uncovered a high viral load specimen that repeatedly tested negative by this antigen test. Whole genome sequencing of the specimen uncovered two mutations, T205I and D399N, present in the nucleocapsid protein of the isolate. All six SARS-CoV-2 positive clinical specimens available in our laboratory with a D399N nucleocapsid mutation and CT < 31 were not detected by the Sofia 2 but detected by the Abbott BinaxNOW COVID-19 Ag Card, while clinical specimens with the T205I mutation were detected by both assays. Testing of recombinant SARS-CoV-2 nucleocapsid with these variants demonstrated an approximate 1000-fold loss in sensitivity for the Quidel Sofia SARS Antigen FIA test associated with the D399N mutation, while the BinaxNOW and Quidel Quickvue SARS Antigen tests were unaffected by the mutation. The D399N nucleocapsid mutation has been relatively uncommon to date, appearing in only 0.02% of genomes worldwide at time of writing. Our results demonstrate how routine pathogen genomics can be integrated into the clinical microbiology laboratory to investigate diagnostic edge cases, as well as the importance of profiling antigenic diversity outside of the spike protein for SARS-CoV-2 diagnostics.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Nucleocapsid/genetics , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL